(Rev. 173, Issued: 11-22-17, Effective: 11-28-17, Implementation: 11-28-17)
§483.25(g) Assisted nutrition and hydration.
(Includes naso-gastric and gastrostomy tubes, both percutaneous endoscopic gastrostomy and percutaneous endoscopic jejunostomy, and enteral fluids). Based on a resident's comprehensive assessment, the facility must ensure that a resident—
§483.25(g)(4)-(5) Enteral Nutrition
§483.25(g)(4) A resident who has been able to eat enough alone or with assistance is not fed by enteral methods unless the resident’s clinical condition demonstrates that enteral feeding was clinically indicated and consented to by the resident; and
§483.25(g)(5) A resident who is fed by enteral means receives the appropriate treatment and services to restore, if possible, oral eating skills and to prevent complications of enteral feeding including but not limited to aspiration pneumonia, diarrhea, vomiting, dehydration, metabolic abnormalities, and nasal-pharyngeal ulcers.
DEFINITIONS §483.25(g)(4)-(5)
“Bolus feeding” is the administration of a limited volume of enteral formula over brief periods of time.
“Continuous feeding” is the uninterrupted administration of enteral formula over extended periods of time.
“Enteral feeding” (also referred to as “tube feeding”) is the delivery of nutrients through a feeding tube directly into the stomach, duodenum, or jejunum.
“Feeding tube” refers to a medical device used to provide liquid nourishment, fluids, and medications by bypassing oral intake. There are two basic categories, naso-grastric and gastrostomy. The type of feeding tube used must be based on clinical assessment and needs of the resident since there are various kinds of feeding tubes within each category.
“Gastrostomy tube” ("G-tube") is a tube that is placed directly into the stomach through an abdominal wall incision for administration of food, fluids, and medications. The most common type is a percutaneous endoscopic gastrostomy (PEG) tube
“Jejunostomy tube” (a.k.a. “percutaneous endoscopic jejunostomy” (PEJ or “J-tube”) is a feeding tube placed directly into the small intestine.
“Naso-gastric feeding tube” ("NG tube") is a tube that is passed through the nose and down through the nasopharynx and esophagus into the stomach.
“Transgastric jejunal feeding tube” (“G-J tube”) is a feeding tube that is placed through the stomach into the jejunum and that has dual ports to access both the stomach and the small intestine.
GUIDANCE §483.25(g)(4)-(5)
A decision to use a feeding tube has a major impact on a resident and his or her quality of life. It is important that any decision regarding the use of a feeding tube be based on the resident’s clinical condition and wishes, as well as applicable federal and state laws and regulations for decision making about life-sustaining treatments
CONSIDERATIONS REGARDING THE USE OF FEEDING TUBES
The regulations at §483.25(g)(4) require that a feeding tube is not used unless there is a valid, clinical rationale, and the resident or if applicable, his/her representative has consented to its use. Consent implies that a discussion has occurred between the resident or representative and the physician, or other member of the treatment team, explaining the process of receiving the tube, and the risks and benefits.
Several factors may be involved in the decision to use a feeding tube including medical conditions that impair the resident’s ability to maintain appropriate nutritional parameters (e.g., cerebrovascular accident, esophageal cancer, delirium, reconstructive facial or oral surgery). The need to improve the resident’s nutritional status or level of comfort are also factors that may be involved in the decision to use a feeding tube. The duration of use of a feeding tube may vary, depending on the clinical situation and resident choice.
The interdisciplinary team, with support and guidance from the physician, is responsible for assuring the ongoing review, evaluation and decision-making regarding the continuation or discontinuation of all treatments, devices or approaches implemented to care for the resident. Involving the resident, family, and/or the resident’s representative in discussions about the indications, use, potential benefits and risks of tube feeding, types of approaches, and alternatives helps support the resident’s right to make an informed decision to use or not use artificial nutrition and hydration.
A clinically pertinent rationale for using a feeding tube includes, but is not limited to:
The use of a feeding tube may potentially benefit or may adversely affect a resident’s clinical condition and/or psychosocial well-being. Examples of some possible benefits of using a feeding tube may include:
Examples of some possible adverse effects of using a feeding tube may include:
In order to assure that the resident being fed by a feeding tube maintains the highest degree of quality of life possible, it is important to minimize possible social isolation or negative psychosocial impact to the degree possible (e.g., continuing to engage in appropriate activities, socializing in the dining room). Because of the possible side- effects and discomfort associated with the use of nasogastric tubes, there should be clinically pertinent documentation for extended use of nasogastric tubes (e.g., greater than 30 days).
Nutrition and feeding issues and their underlying causes in the resident with advanced dementia or other chronic neurological disorders such as Parkinson’s disease present a particular set of issues and considerations that are discussed in F692. The extended use of enteral feeding tubes in individuals with advanced dementia does not necessarily extend life and remains controversial. The literature regarding enteral feeding of these individuals suggests that there is little evidence that enteral feeding improves clinical outcomes (e.g., prevents aspiration or reduces mortality).
CONSENT
A feeding tube should not be placed unless consented to by the resident or if applicable, appropriately authorized resident representative. The resident has the right to make an informed decision about the treatment they receive. If a resident had a feeding tube placed prior to admission or in another care setting the physician and interdisciplinary care team must review the basis (e.g., precipitating illness or condition change) for the initial placement of the feeding tube and the resident’s current condition. This is to determine if there is a continued rationale for its use and to ensure that its continued use is consistent with the resident's treatment goals and wishes. Decisions to continue or discontinue the use of a feeding tube are made through collaboration between the resident (or a representative for a resident who lacks capacity to make and communicate such decisions), the physician, and the interdisciplinary care team. This includes a discussion of the relevance of a feeding tube to attaining a resident’s goals (e.g., whether the nutritional intervention is likely to have a significant impact on the individual’s underlying condition or overall status).
TECHNICAL AND NUTRITIONAL ASPECTS OF FEEDING TUBES
It is important that staff providing care and services to the resident who has a feeding tube are aware of, competent in, and utilize facility protocols regarding feeding tube nutrition and care. These protocols are required to be developed with the medical director in order to assure staff implement and provide care and services according to resident needs and professional standards of practice.
Facility policies and procedures regarding the technical aspects of feeding tubes must be developed and implemented, which address:
Monitoring the feeding tube
How to verify that the tube is functioning before beginning a feeding and before administering medications, which may include:
NOTE: Auscultation is no longer recommended for checking placement of the feeding tube. Movement of air would likely be heard whether the tube was in the correct or incorrect location. X-ray confirmation is the most accurate method for verification of tube placement when concerns arise regarding dislodgement or placement. Additional information regarding monitoring of feeding tubes may be found at, https://www.ismp.org/tools/articles/ASPEN.pdf
NOTE: References to non-CMS/HHS sources or sites on the Internet included above or later in this document are provided as a services and do not constitute or imply endorsement of these organizations or their programs by CMS or the U.S. Department of Health and Human Services. CMS is not responsible for the content of pages found at these sites. URL addresses were current at the date of this publication.
Care of the feeding tube
Feeding tube replacement. Direction for staff regarding the conditions and circumstances under which a tube is to be changed, such as:
Nutritional Aspects of Feeding Tubes
When a resident is receiving nutrition via a feeding tube, the practitioner and the interdisciplinary team identify the resident’s nutritional needs and facility procedures that direct staff in providing care and services to the resident. The practitioner’s orders related to tube feeding typically include the following components: kind of feeding and its caloric value; volume, duration, and mechanism of administration (e.g., gravity or pump); and frequency of flush.
Facility procedures regarding the nutritional aspects of feeding tubes include, but are not limited to:
Enteral nutrition. Direction to staff regarding the nutritional product and meeting the resident’s nutritional needs such as:
Flow of feeding. Direction for staff regarding how to manage and monitor the rate of flow, such as:
Complications Related to the Feeding Tube
An enteral feeding tube may be associated with significant complications, including aspiration, leaking around the insertion site, abdominal wall abscess, or erosion at the insertion site including the nasal areas. Feeding tubes can perforate the stomach or small intestine, with resultant peritonitis. Esophageal complications of feeding tubes may also occur including esophagitis, ulcerations, strictures, and tracheoesophageal fistulas. The use of tubes not designed or intended for enteral feeding may increase the risk of complications.16, 17
Tubes may clog for various reasons, including plugging by formula, pill fragments, or the precipitation of medications incompatible with the formula.18 Flushing feeding tubes regularly and in association with medication administration, as indicated by current professional standards of practice and provided in the resident care policies, can help reduce the risk of clogging.
Complications Related to the Administration of the Enteral Nutrition Product The administration of an enteral nutrition product may be associated with other complications including, but not limited to, nausea, vomiting, diarrhea, abdominal cramping, inadequate nutrition and aspiration. Additionally, interactions between the formula and various medications can affect the absorption and/or effectiveness of the medication. For example, the effectiveness of phenytoin sodium (Dilantin, Phenytek) may be reduced by the drug binding with the enteral feeding's protein component, leading to less free drug availability and possibly inadequate therapeutic levels.
Metabolic complications related to tube feeding may include inadequate calorie or protein intake, altered hydration, hypo- or hyperglycemia, and altered electrolyte and nutrient levels. These risks may be reduced by calculating the nutritional needs of the resident, taking into account comorbid conditions and medications that affect these balances, monitoring for adequate nutritional status and complications, and adjusting the tube feeding accordingly.
While a feeding tube may be initiated with the intent to address certain medical conditions, the use of a feeding tube does not necessarily decrease the risk of aspiration for individuals with other risk factors, such as moderate or less severe swallowing abnormalities. Aspiration risk may potentially be affected by factors such as diminished level of consciousness, improper positioning of the resident during administration of the feeding, and failure to assure the feeding tube is correctly positioned within the stomach or intestine. The evidence is inconsistent and conflicting regarding any connection between gastric residual volume (GRV) and the risk or occurrence of aspiration.19
Risk of aspiration should be assessed individually and appropriate interventions (e.g., proper positioning, rate of flow) implemented accordingly. There may be situations where other coexisting factors influence decisions about elevating the head of the bed; for example, a resident being fed by a tube who may be at risk for shearing by sliding down the sheets when the head of the bed is elevated to a recommended angle.
Complications Management
The facility is expected to identify and address actual or potential complications related to the feeding tube or tube feeding and to notify and involve the practitioner in evaluating and managing care to address these complications and risk factors.
PROCEDURES §483.25(g)(4)-(5)
Use the Tube Feeding Critical Element (CE) Pathway along with the above guidance when determining if the facility utilized a feeding tube only after adequate assessment of the resident’s clinical condition to ensure this intervention is medically necessary and with the resident’s consent.
The surveyor(s) should use the following: observations, interviews and record reviews to determine if a feeding tube is utilized only if the resident’s clinical condition makes this intervention medically necessary and with the resident’s consent. The surveyor must determine if a feeding tube is utilized in accordance with current professional standards of practice and if services are provided to prevent complications to the extent possible.
Additionally, for a resident whose goal is to restore normal eating skills to the extent possible, the surveyor must determine if the necessary care and services were provided to reach this goal. If there are concerns regarding the facility’s use and care of feeding tubes, review facility policies and practices with regard to the use and care of feeding tubes.
KEY ELEMENTS OF NONCOMPLIANCE
To cite deficient practice at F693, the surveyor's investigation will generally show that the facility failed to do one or more of the following:
DEFICIENCY CATEGORIZATION
In addition to actual or potential physical harm, always consider whether psychosocial harm has occurred when determining severity level (See Appendix P, Section IV, E, Psychosocial Outcome Severity Guide).
An example of Severity Level 4 Noncompliance : Immediate Jeopardy to Resident Health or Safety, includes but is not limited to:
An example of Severity Level 3 Considerations: Actual Harm that is Not Immediate Jeopardy includes, but is not limited to:
Examples of Severity Level 2 Noncompliance: No Actual Harm with Potential for More than Minimal Harm that is Not Immediate Jeopardy includes, but is not limited to:
Severity Level 1: No Actual Harm with Potential for Minimal Harm
The failure of the facility to provide appropriate care and services for feeding tubes, places the resident at risk for more than minimal harm. Therefore, Severity Level 1 does not apply for this regulatory requirement.
POTENTIAL TAGS FOR ADDITIONAL INVESTIGATION
If there are concerns identified regarding the resident receiving adequate nutrition/hydration when receiving tube feeding, review F692, Assisted Nutrition and Hydration, for further investigation.
If there is lack of consent related to the placement of a feeding tube, cite those deficiencies here instead of the Resident Rights since this regulatory language is specific to consent for a feeding tube.